Valid in Perpetuity
The loan licence does not expire after five years merely because a five-year block ends.
A Medical Device Loan Licence allows an applicant to use the manufacturing premises and infrastructure of another licensed medical device manufacturer, subject to the applicable State or Central Licensing Authority requirements.
LexAccord Global supports device classification, host-site eligibility, manufacturing agreements, QMS and technical dossiers, Form MD-4/MD-8 filing, audit or inspection coordination, regulatory query management and five-year retention compliance.
Maintain active status through the prescribed five-year retention fee cycle.
A Medical Device Loan Licence is a statutory manufacturing authorization that enables an applicant to manufacture medical devices using another manufacturer's licensed premises and facilities. The loan-licensee remains subject to MDR 2017 manufacturing, quality, vigilance, change-control and recordkeeping obligations.
The regulatory route depends on risk class: Class A/B applications are handled by the State Licensing Authority, while Class C/D applications are handled by the Central Licensing Authority. For Class C/D, CDSCO's current checklist specifically requires the host manufacturer's licence to show that the facility is licensed for the same applied device or devices.
Last reviewed: 30 August 2026 · Primary basis: MDR 2017 Rules 20–30, Second Schedule; CDSCO Form MD-10 loan-licence checklist
The Second Schedule applies the same site-and-device fee structure to manufacturing licences and loan licences.
| Risk Class | Application Form | Loan Licence | Licensing Authority | Site Fee | Each Distinct Device |
|---|---|---|---|---|---|
| Class A / B | Form MD-4 | Form MD-6 | State Licensing Authority | ₹5,000 | ₹500 |
| Class C / D | Form MD-8 | Form MD-10 | Central Licensing Authority | ₹50,000 | ₹1,000 |
Share your risk classes, host manufacturing site and device grouping so the site/device fee and correct application route can be mapped before submission.
Rule 29 provides perpetual validity for Form MD-6 and MD-10 unless suspended or cancelled, provided the licence-retention fee is paid before completion of every five-year period.
The loan licence does not expire after five years merely because a five-year block ends.
₹5,000 + ₹500/device for Class A/B or ₹50,000 + ₹1,000/device for Class C/D, based on the endorsed scope.
Late fee is calculated at 2% of the licence retention fee for every month or part thereof within 180 days.
If the retention fee and applicable late fee remain unpaid during the 180-day window, the licence is deemed cancelled.
The Rules prescribe stage-specific timelines rather than one universal approval SLA. The practical timeline depends on the device class, audit/inspection requirement, host-site readiness and whether deficiencies are raised.
| Risk Class | Statutory / Regulatory Sequence | Practical Planning Range | Key Note |
|---|---|---|---|
| Class A | SLA grant/rejection within 45 days; no pre-grant site audit | ~1–2 months | Notified Body audit is conducted after grant within 120 days |
| Class B | Notified Body audit within 90 days; report within 30 days; SLA decision within 20 days after report | ~2–4 months | Audit scheduling and closure of findings materially affect timing |
| Class C / D | CLA scrutiny within 45 days; inspection within 60 days where required; decision within 45 days of inspection report | ~3–6 months | Fresh inspection is not required for a loan licence if the host site is already licensed for the same device |
The pathway is designed for businesses that want legal manufacturing authorization while leveraging an eligible third-party manufacturing facility.
From host-site diligence through Form MD-6/MD-10 and post-approval retention.
Risk classification, authority mapping, host licence scope, QMS capability and contract-manufacturing readiness.
Application records, manufacturing agreement, declarations, applicant documents and host-site regulatory evidence.
Technical documentation, labelling, Essential Principles, risk analysis, validation evidence and applicable Device/Plant Master File material.
Form MD-4 or MD-8 filing, fee coordination, Notified Body audit/CLA inspection support and deficiency-response management.
Form MD-6/MD-10 verification and support for adding additional devices to the approved manufacturing site.
Retention fee calendar, change control, PMS/vigilance, manufacturing records and ongoing licence-condition support.
Using a host facility does not remove the licence holder's regulatory responsibilities.
Confirm Class A/B vs C/D, licensing authority and correct form.
Verify licence scope, QMS, technical capability and manufacturing agreement.
Prepare MD-4/MD-8, technical records and site/device government fee.
Submit through the applicable medical-device online workflow.
Coordinate Notified Body audit or CLA inspection where required.
Verify grant, implement licence conditions and track five-year retention.
We check manufacturing scope and QMS readiness before commercial agreements turn into regulatory bottlenecks.
Class A, B and C/D applications are planned against their actual audit, scrutiny and inspection sequences rather than one generic timeline.
Device documentation, labelling, QMS evidence and host-facility documentation are reconciled into one defensible filing package.
A Medical Device Loan Licence allows an applicant to manufacture medical devices using the manufacturing premises and facilities of another licensed manufacturer, subject to the Medical Devices Rules, 2017 and the applicable State or Central Licensing Authority requirements.
For Class A and Class B medical devices, the loan-licence application is made in Form MD-4 to the State Licensing Authority. If approved, the loan licence is issued in Form MD-6.
For Class C and Class D medical devices, the loan-licence application is made in Form MD-8 to the Central Licensing Authority. If approved, the loan licence is issued in Form MD-10.
The Second Schedule prescribes ₹5,000 for one manufacturing site plus ₹500 for each distinct Class A or Class B medical device.
The Second Schedule prescribes ₹50,000 for one manufacturing site plus ₹1,000 for each distinct Class C or Class D medical device.
Form MD-6 and Form MD-10 remain valid in perpetuity unless suspended or cancelled, subject to payment of the applicable licence retention fee before completion of every five-year period from the date of issue.
The retention fee follows the same site-and-device fee schedule: ₹5,000 per Class A/B site plus ₹500 per distinct Class A/B device, or ₹50,000 per Class C/D site plus ₹1,000 per distinct Class C/D device.
If the retention fee is not paid by the due date, a late fee of 2% of the retention fee applies for every month or part thereof for up to 180 days. If payment is still not made during that period, the licence is deemed cancelled.
Rule 20 provides a 45-day period for the State Licensing Authority to grant or reject a Class A licence or loan licence after application. No pre-grant manufacturing-site audit is required for Class A, although a Notified Body audit is required within 120 days after grant.
For Class B, a Notified Body audit is required before grant. The Rules provide up to 90 days for the audit, 30 days for the Notified Body to submit its report, and 20 days for the State Licensing Authority to grant or reject after receiving the audit report. Actual timelines depend on audit scheduling and dossier readiness.
For Class C and D, the Central Licensing Authority has a 45-day technical-scrutiny stage. Where inspection is required, the manufacturing site is to be inspected within 60 days, followed by a grant or rejection decision within 45 days of receipt of the inspection report. A complete loan-licence application can avoid a fresh site inspection where the host manufacturing site is already licensed for the same device.
For Class C and D loan-licence applications, CDSCO's checklist requires a copy of the host manufacturer's manufacturing licence showing that its facility is licensed for the same applied device or devices. Host-site scope should therefore be checked before filing.
Yes. The manufacturing site must comply with the Quality Management System requirements in the Fifth Schedule of MDR 2017. Technical staff, testing controls, device documentation and applicable standards also form part of the licensing framework.
Yes. A loan-licence model can support an asset-light market-entry strategy where a startup or brand owner uses an eligible licensed manufacturing facility instead of establishing a separate plant.
The licence holder must maintain manufacturing and sales records, batch testing, competent technical supervision, change-control compliance, vigilance and recall obligations, and an audit or inspection book in Form MD-11, among other conditions in Rule 26.
Get the device class, host facility, government fee, audit route and retention framework mapped before submission.
Share your device class and manufacturing model and our regulatory team can review the pathway.
Partner with LexAccord Global to simplify regulatory compliance, reduce approval risks, and unlock new business opportunities through expert consulting and end-to-end market access solutions.